Bonded Wire Ribbon Cable

Conductors:
Solid, Bare Stranded, Tinned Stranded,  Heavy Tinned Stranded, Topcoat, Prebond, Overcoat

View Schedule

UL Appliance Wire Style 2957 105c - 300 Volts

Atlas Part Number AWG Conductor Cond. Diam. Approximate OD in inches Approximate
LBS./M FT.
Std. Put-Up
in mm
2407T1569.2.BOND 24 7/32 0.024 0.610 .056"  x  .112" 5.54 5 M/FT
2207T1569.2.BOND 22 7/30 0.030 0.762 .062"  x  .124" 7.30 5 M/FT
2010T1569.2.BOND 20 10/30 0.038 0.965 .070"  x  .140" 9.58 2.5 M/FT
1816T1569.2.BOND 18 16/30 0.048 1.219 .080"  x .160" 13.96 2.5 M/FT
1626T1569.2.BOND 16 26/30 0.059 1.499 .092"  x  .184" 20.90 2.5 M/FT
1441T1569.2.BOND 14 41/30 0.075 1.905 .107"  x  .214" 31.12 2.5 M/FT

Ribbon width can be 2 to 8 conductors.

Insulated Singles: Labeled with AWM style 1569 - 150c and 300v.

UL Appliance Wire Style 2474  105c - 600 Volts

Atlas Part Number AWG Conductor Cond. Diam. Approximate OD in inches Approximate
LBS./M FT.
Std. Put-Up
in mm
2407T1015.2.BOND 24 7/32 0.024 0.610 .086"  x  .172" 9.40 2.5 M/FT
2207T1015.2.BOND 22 7/30 0.030 0.762 .092"  x .184" 11.60 2.5 M/FT
2010T1015.2.BOND 20 10/30 0.038 0.965 .100"  x .200" 14.60 2.5 M/FT
1816T1015.2.BOND 18 16/30 0.048 1.219 .110"  x .220" 19.40 2.5 M/FT
1626T1015.2.BOND 16 26/30 0.059 1.499 .121"  x .242" 26.80 2.5 M/FT
1441T1015.2.BOND 14 41/30 0.075 1.905 .137"  x .274" 38.20 2.5 M/FT

Ribbon width can be 2 to 8 conductors.

Insulated Singles: Labeled or complying with manufacturers AWM procedure having a minimum rating of 105c and 600v.